2021 2nd Alert HiPo14 Floorman got hit by power tong
On 21st February, 2021 @ 22:54 hours, while pulling out and laying down 3 1/2" tubing, the power tong suddenly swung while breaking the connection (11th Joint) and pushed the floor-man backward, falling to ground. No injury reported.
Always adhere to standard operating procedures. While breaking out torqued connection, start with low gear on the power tong Regular checks of die condition to ensure they are clean Always use correct length snub/Safety line Dedicated tagged snub lines to be kept with store man