2019 Second Alert HiPo#07 PTW
Mechanical crew attempted to brake flange of a 2” injection manifold which was connected to 20” sour liquid line without valid PTW and isolation certificate and without donning BA sets While opening the bolt crew smelt H2S gas and stopped the activity
Always confirm lines are positively isolated Always ensure permit available for the activity Always remember that you are authorized to stop unsafe activity Always consider a process line to be ‘live’ unless proven otherwise Only open lines with the use of the proper PPE, in this case with BA sets donned. Lifesaving rules are made to save lives, follow it