Sign In
2018 Second Alert - SA001_HiPo01
During running in 4 1/2" completion tubing joint # 44, the Driller side air winch line caught in the extended TDS link tilt bracket causing parting of the winch line. The tail chain of winch line dropped 9 meters to the rig floor, and a 1.2 Ton power tong dropped from a height of 80 cm to rig floor. The dropped tail chain hit the TDS link tilt hydraulic hose which got punctured.
Ensure winch line is free from obstacles. Report all Near miss no matter how small, in timely manner so that it is investigated and lesson learnt Stop the operation if you see anything unsafe. Ensure to discuss potential dynamics drops in pre job meeting (JSA / TRIC) Always adhere to red zone management

Category:Second AlertsDocument Type:Safety
Format:.pptxViewers:14