2021 2nd Alert HiPo12 Bail slip during lifting, hit V door gate caused to drop to the round
On 31st January,2021 @ 11:05 hours, while lowering the third party casing bail at rig floor by using the crane, bail lower end slipped towards v-door on wooden surface (set back area) and hit the V-door gate. V-door gate one part (right side) came out from the hinge and slide down v-door to the ground. No injury reported
Always ensure temporary No Go Zone is managed all the times during picking up / laying down activity in the cat-walk area Always use correct rigging & lifting method while lifting long loads Always use lift plan and risk assessment to perform any lifting activities ‘’ 10 questions for safe lifting’’ Always use tagline/hands off tools to guide the load Always keep good communication between banks-man and crane operator. Always ensure equipment at height having secondary retention