2020 2nd alert HiPo#63 (Drops) DP slipped & dropped from the elevator
RIH 4 1/2'' RTTS on 2 7/8" HT PAC Drill Pipes from pipe racks was in progress. The 13th joint was hanging from the 2 7/8” slip type B&V Elevator in order to make-up with power tong. There was an issue observed with power tong that required fixing and it was decided to keep the drill pipe out of the floor next to the V door hanging. At that moment the drill pipe suddenly slipped thru the elevator and fell down to the ground.
Check the elevator C plate and HT Pac pipe tool joint OD prior to every tripping and maintain the records in the Elevator check list (ensure the SOP for handling of HT Pac Pipes is always followed with stress to checking prior the tripping). Ensure the C plate is inspected for acceptance at every Elevator Inspection interval. Always comply to the Drops zone management, utilize step back safety zone whenever possible.