2019 Second Alert HiPo#01 Lifting
On Friday 10th of January 2019 on the Fahud compression project, a Mechanical crew were engaged in lifting operation using a 3.3 TON / 5.5m side boom loader for 24 inch 24m GRE pipes. While moving the load the lifting belt slipped out of the hook causing one side of the boom to drop which luckily resulted is minor damage and no injury
Always fully comply with the approved lift plan. Use the correct equipment for the correct purpose as described in the approved lift plan. Always intervene for any unsafe action Only lift when the lifting supervisor is present Always use the 10 questions for a safe lift When in doubt don’t lift