You can continue browsing, but please use a supported browser to improve your experience.
The tension in the compensator assembly broke the connection between the piston rod and the compensator piston (screwed connection). The piston rod together with the tri-pod fell down and hit the side of the spider elevator. On impact the safety split pin from the hinge pin sheared. This resulted in a disconnection of the shackle and piston rod. The piston rod and the shackle weighing 3 kg. fell down on the rig floor from a height of about 13 m.