2020 2nd alert LTI#03 (Finger) got caught between pipe and elevator
While POOH and laying down of 5”drill pipes, Floor man was latching the drill pipe elevator to the drill string on rotary . While doing so ,his finger got trapped between the elevator and the drill pipe joint causing left hand thump to get injured. He was immediately taken to the clinic and then taken to nearby hospital for further examination.
Ensure people are not in contact with any mechanical hazards on Rig-floor such as moving items, suspended loads or unstable handling tools. Ensure work is well controlled on rig floor and people are not distracted by any side communications or multi tasks. Ensure proper process in place to utilize CCTV for monitoring, intervening and learnings.